242
Former of signals A361
Просмотров242
Открытий контактов0
Автоподстановок0

Former of signals A361

Цена по запросу
В наличии
'Specifications_without_split': 'Production Products: 1. The measurement range of a static clearance for 5 mm coil: 0.2 ... 2.2 mm. The measurement range for the static clearance for 8 mm coil: 0.3 ... 3.3 mm. Scope of the measured relative vibration digging for 5 mm coil: 0.125; 0.25; 0.5 mm. Scope of the measured relative vibration digging for 8 mm coil: 0.25; 0.5; 1 mm. Transformation coefficients when measuring the scope of relative movement by exiting permanent current of 4-20 mA for 5 mm coil: 128; 64; 32 MKA/MKM. Transformation coefficients when measuring the scope of relative movement by exiting permanent current of 4-20 mA for 8 mm coil: 64; 32; 16 MKA/μm. The transformation coefficients when measuring the static clearance with a permanent current of 4-20 mA for 5 mm coil: 8 μA/μm. The transformation coefficients when measuring the static clearance with a permanent current of 4-20 mA for 8 mm coil: 5.3 mA/μm. The error of the task of transformation coefficients: ± 5%. The nonlinearity of the amplitude characteristics: ± 5%. The operating frequency range (uneven frequency response ± 1 dB): 2 ... 10,000 Hz. Range of operating temperatures: -30 ... 65 ° C. The measurement error in the working temperature range: ± 2%. The operating temperature range of the sensor: -40 ... 150 ° C. The measurement error in the working temperature range with the sensor: ± 10%. Power voltage: + (18 ... 30) V. Consumption: & lt; 35 mA. The level of SKZ of its own noise for 5 mm coil: None. The level of SKZ of its own noise for 8 mm coil: None. Input connector: terminal. Lesson connector: terminal. The length of the sensor cable: 0.5 ... 18 m. Mass: 150 g. Mount on DIN - rail: yes. Appointment: in combination with the sensor, it forms a tool for measuring vibration and moving parts of machines and mechanisms .. Feature: Exiting 4-20 mA of relative vibro-digging OUT (D); The output of the 4-20 mA of the static gap OUT (S); high temperature and temporary stability of characteristics; the ability to replace the same type of primary converters; Transfer of the output \ ntok signal to a distance of up to 1000 m. '}

Другие товары от этого поставщика

133
GTLab
Смотреть товар на сайте поставщика
Цена по запросу
В наличии,
доставка из г. Саров
144
GTLab
Смотреть товар на сайте поставщика
Цена по запросу
В наличии,
доставка из г. Саров
106
GTLab
Смотреть товар на сайте поставщика
Цена по запросу
В наличии,
доставка из г. Саров
174
GTLab
Смотреть товар на сайте поставщика
Цена по запросу
В наличии,
доставка из г. Саров
Показать все товары этого поставщика